dc.description.abstract | En Chile las estructuras industriales se encuentran normadas por la
NCh2369.0f2003 (Diseño sísmico de estructuras e instalaciones industriales)
que entrega los requisitos y exigencias mínimas que deben cumplir estas
estructuras. Sin embargo, esta norma no asegura el correcto funcionamiento
operacional y de seguridad de las estructuras industriales, por lo que es labor
fundamental del ingeniero lograr la estructuración funcional requerida.
El objetivo de esta memoria es determinar la suficiencia de los requisitos de
diseño normativos establecidos en la NCh2369.0f2003 para estructuras que
posean arriostramientos concéntricos en configuración Cruz y V invertida. En
aquellos casos que se visualicen falencias normativas, se proponen requisitos
complementarios que ayuden a lograr los objetivos que la filosofía de diseño
sismo-resistente en Chile establece para las estructuras industriales. Para
lograr el objetivo se diseñaron 2 estructuras chilenas reales (Un Silo de 650
toneladas, dividido en 4 escenarios, y un Marco Arriostrado de un edifico
industrial) de acuerdo con la NCh2369.0f2003 y se verificaron mediante análisis
tiempo-historia no lineales con registros artificiales compatibles al espectro de
demanda correspondiente a zona sísmica 3 y suelo tipo 11., lugar donde se
encuentran dichas estructuras. Mediante este análisis se muestra que el diseño
elástico no es suficiente para la estructura del silo en sus 4 escenarios, puesto
que sus elementos columnas plastifican, generando el colapso estructural. Con
la propuesta de diseño implementada, se logra un mejor diseño de la estructura,
evitando el colapso producido por plastificaciones en la columna. Por otra parte,
el marco plano no colapsa, por lo que parece suficiente el diseño elástico de la
NCh2369.0f2003. | es_CL |
dc.description.abstract | In Chile industrial structures are regulated by the NCh2369.0f2003 find
(seismic design of structures and industrial facilities) that provides the
requirements and minimum requirements to be met by these structures.
However, this rule does not ensure the correct operational and safety of
industrial structures functioning, so it is vital work of the engineer achieve the
required functional structure.
The Aim of this report is to determine the adequacy of regulatory
requirements set out in NCh2369.0f2003 design for structures having concentric
bracings in inverted V configuration Cross. In cases where regulatory failures
are displayed, additional requirements that help achieve the objectives that the
philosophy of seismic-resistant design in Chile is set for industrial structures are
proposed. To achieve the objective two real Chilean structures were designed
(A Silo of 650 tonnes, divided into 4 stages, and Bracing frame industrial
building) according to NCh2369.0f2003 were designed and verified by analyzing
nonlinear time-history with records compatible spectrum corresponding demand
for seismic zone 3 and artificial soil type 11., where such structures are found.
This analysis shows that the elastic structure desigrí is not sufficient for silo in its
4 scenarios, since all plasticized elements, including columns, which generate
structural collapse. lmplemented with the proposed design is achieved a correct
design of the structure, preventing the collapse produced by laminations over
the column. By the other hand the plane framework does not collapse, so it is
sufficient the elastic design for NCh2369.0f2003. | |
dc.language.iso | es | es_CL |
dc.publisher | Universidad Andrés Bello | es_CL |
dc.subject | Construcciones de Hormigón Armado | es_CL |
dc.subject | Efectos Sísmicos | es_CL |
dc.subject | Análisis Estructural | es_CL |
dc.subject | Ingeniería Estructural | es_CL |
dc.subject | Chile | es_CL |
dc.title | Análisis inelástico de estructuras industriales arriostradas: análisis pos-pandeo de configuración crus y v invertida | es_CL |
dc.type | Thesis | es_CL |