Mandiola, EduardoAlarcón, EduardoMontero, CarolinaPulleghini, Marcosdel Sol, MarianoOlave, EnriqueOñate, Juan C2014-02-262016-05-312014-02-262016-05-312012International Journal of Morphology. Vol. 30 N° 3, 2012.0717-9502http://dx.doi.org/10.4067/S0717-95022012000300046http://repositorio.unab.cl/xmlui/handle/ria/2374Indexación: Web of Science; ScieloLas implicancias clínicas que tienen los procesos oclusivos de la Arteria Coroidea Anterior (AChA), son de considerable importancia y nos han motivado para efectuar su análisis biométrico incorporando algunos otros parámetros. Para su ejecución, se utilizaron cerebros inyectados con látex coloreado de rojo fijados en solución de formol, provenientes del Servicio Médico Legal, Santiago.Para su observación, se usó lupa luminiscente 4 X y las mediciones efectuadas con Caliper Mitutoyo Digital. Esta arteria se originó de la Carótida Interna (ACI) en un 83,3 % y en un 16,7 % de la Arteria Comunicante Posterior (ACoP ). El calibre medio observado en su origen fue de 0,68 ± 0,31 mm; en el tercio medio de 0,60 ± 0,21 mm; en el punto de entrada en el plexo coroideo de 0,48 ± 0,23 mm. La longitud media desde el origen de la AChA al plexo coroideo fue de 28,67 ±6,33 mm; la distancia media desde su origen al de la ACoP fue de 6,97 ± 4,89 mm. El número promedio de ramas perforantes registradas fue de 6. Nuestros resultados pueden ser una contribución a considerar en la clínica.SUMMARY:The clinical implications of occlusive processes in the anterior choroidal artery (AChA) are of considerable importance and have motivated us to perform a biometrical analysis of the afore mentioned artery including new biometric parameters (measurements). This study was perfomed on vascularized brains that were both fixed with for formalin solution and injected whith red tinted latex and brains that were not fixed with formalin solution, which were obtained from the Medical Legal Service, Santiago. They were observed using a luminescent 4 X magnifying glass and the measurements perfomed using a Mitutoyo Digital Caliper. This artery originated from the internal carotid artery (ICA) in 83.3 % of the cases observed, and in 16.7 % it originated from the posterior communicating artery ( PCoA). The mean caliber (diameter) of the artery was 0.68 ± 0.31 mm at the point of origin; the middle third was 0.60 mm ± 0.21 mm; at the point of entry into the choroidal plexus it was 0.48 mm ± 0.23 mm. The mean length from its origin at the AChA to the choroidal plexus was 28.67 mm ± 6.33 mm; the mean distance from its origin at the PCoAwas 6.97mm± 4.89 mm. The number of perforating branches of the AChA was 6. Our results can be considered a clinical contribution. KEY WORDS : Anterior choroidal artery ; Biometry; Cephalix index; Internal carotid artery.esArteria coroidea anterior; Biometría; Índice cefálico; Arteria carótida interna, Anterior choroidal artery ; Biometry; Cephalix index; Internal carotid artery.Características Biométricas de la Arteria Coroidea Anterior en su Segmento CisternalBiometrical Characteristics of Anterior Choroidal Artery in its Cisternal SegmentArtículo