Examinando por Autor "Intelangelo, Leonardo"
Mostrando 1 - 2 de 2
Resultados por página
Opciones de ordenación
Ítem Dynamometric Strength Profile of Hip Muscles in Youth Soccer Players(MDPI, 2023-01) Contreras-Díaz, Guido; Chirosa-Ríos, Luis Javier; Riego-Ruiz, Antonio; Intelangelo, Leonardo; Tuesta-Roa, Marcelo; Morales-Zúñiga, Jorge; Jerez-Mayorga, DanielBackground: Soccer is the most widely practiced sport in the world, demanding high-speed activities such as jumps, sprints and changes of direction. Therefore, having optimal levels of muscle strength improves performance and reduces the injury rate. Objectives: The objectives of our study were (i) to determine the dynamometric profile of hip muscle strength in young soccer players by position, evaluated at different isokinetic speeds, (ii) to describe the conventional and functional unilateral muscle strength ratios, (iii) to analyze the bilateral balance. Methods: Thirty-seven male soccer players (age 17.02 ± 0.92 years) participated in the study. Strength assessment was performed with a functional electromechanical dynamometer, and concentric and eccentric strength of abductors, adductors, extensors and hip flexors were measured bilaterally at 0.5 m/s and 1 m/s. Results: For eccentric right hip abduction at 0.5 m/s, defenders are significantly stronger than midfielders (p = 0.013) and stronger than forwards (p = 0.140). For eccentric right hip adduction at 0.5 m/s, defenders are significantly stronger than midfielders (p = 0.005) and stronger than forwards (p = 0.253), as for eccentric right hip adduction at 1 m/s, defenders are significantly stronger than midfielders (p = 0.014) and stronger than forwards (p = 0.084). There is a significant effect for the conventional strength ratio of left abduction/adduction at 1 m/s. The conventional strength ratio of forwards is significantly higher than that of defenders (p = 0.045) and higher than that of midfielders (p = 0.152). Conclusions: Concentric and eccentric hip strength values differ according to playing position. © 2023 by the authors.Ítem Test–Retest Reliability of Functional Electromechanical Dynamometer on Five Sit-to-Stand Measures in Healthy Young Adults(MDPI AG, 2021-06) Jerez-Mayorga, Daniel; Huerta-Ojeda, Álvaro; Chirosa-Ríos, Luis; Guede-Rojas, Francisco; Guzmán, Iris; Intelangelo, Leonardo; a Miranda-Fuentes, Claudia; Delgado-Floody, PedroBackground: The purpose of this study was to determine the reliability for the strength and movement velocity of the concentric phase from the five Sit-to-Stand (5STS), using three incremental loads measured by a functional electromechanical dynamometer (FEMD) in healthy young adults. Methods: The average and peak strength and velocity values of sixteen healthy adults (mean ± standard deviation (SD): age = 22.81 ± 2.13 years) were recorded at 5, 10 and 15 kg. To evaluate the reliability of FEMD, the intraclass correlation coefficient (ICC), standard error of measurement (SEM) and coefficient of variation (CV) were obtained. Results: Reliability was high for the 10 kg (CV range: 3.70–4.18%, ICC range: 0.95–0.98) and 15 kg conditions (CV range: 1.64–3.02%, ICC: 0.99) at average and peak strength, and reliability was high for the 5 kg (CV range: 1.71–2.84%, ICC range: 0.96–0.99), 10 kg (CV range: 0.74–1.84%, ICC range: 0.99–1.00) and 15 kg conditions (CV range: 0.79–3.11%, ICC range: 0.99–1.00) at average and peak velocity. Conclusions: The findings of this study demonstrate that FEMD is a reliable instrument to measure the average and peak strength and velocity values during the five STS in healthy young adults. © 2021 by the authors. Licensee MDPI, Basel, Switzerland.