Examinando por Autor "Jara, C.C."
Mostrando 1 - 2 de 2
Resultados por página
Opciones de ordenación
Ítem Asociación predictiva entre parámetros de condición física y dimensiones de calidad de vida relacionada con la salud en adultos mayores chilenos insertos en la comunidad(Sociedad Médica de Santiago, 2017-01) Rojas, F.G.; Ríos, L.J.C.; Urra, S.F.; Ríos, C.V.; Díaz, D.U.; Jara, C.C.; González, P.B.; Aburto, J.C.Background: There is no conclusive evidence about the association between physical fitness (PF) and health related quality of life (HRQOL) in older adults. Aim: To seek for an association between PF and HRQOL in non-disabled community- dwelling Chilean older adults. Material and Methods: One hundred and sixteen subjects participated in the study. PF was assessed using the Senior Fitness Test (SFT) and hand grip strength (HGS). HRQOL was assessed using eight dimensions provided by the SF-12v2 questionnaire. Binary multivariate logistic regression models were carried out considering the potential influence of confounder variables. Results: Non-adjusted models, indicated that subjects with better performance in arm curl test (ACT) were more likely to score higher on vitality dimension (OR > 1) and those with higher HGS were more likely to score higher on physical functioning, bodily pain, vitality and mental health (OR > 1). The adjusted models consistently showed that ACT and HGS predicted a favorable perception of vitality and mental health dimensions respectively (OR > 1). Conclusions: HGS and ACT have a predictive value for certain dimensions of HRQOL.Ítem Validity and reliability of evaluating hip abductor strength using different normalization methods in a functional electromechanical device(Public Library of Science, 2018-08) Vega, E.C.; Jerez-Mayorga, D.; Payer, R.M.; Jara, C.C.; Guzman-Guzman, I.; Ponce, A.R.; Chirosa, L.J.The hip abductor muscles are vitally important for pelvis stability, and common strength deficits can negatively affect functionality. The muscle strength can be measured using different dynamometers and be evaluated in three positions (side-lying, standing, and supine). Obtained strength data can be expressed in different ways, with data normalization providing more objective and comparable results. The aim of this study was to establish the validity and reliability of three protocols in evaluating the isometric strength of the hip abductor muscles. A new functional electromechanical dynamometer assessed strength in three positions, with findings subjected to three data normalization methods. In two identical sessions, the hip abductor strengths of 29 subjects were recorded in the side-lying, standing, and supine positions. Peak force was recorded in absolute terms and normalized against body mass, fat-free mass, and an allometric technique. The peak force recorded in the side-lying position was 30% and 27% higher than in the standing and supine positions, respectively, independent of data normalization methodology. High inter-protocol correlations were found (r: 0.72 to 0.98, p 0.001). The supine position with allometric data normalization had the highest test-retest reliability (0.94 intraclass correlation coefficient and 5.64% coefficient of variation). In contrast, the side-lying position with body mass data normalization had a 0.66 intraclass correlation coefficient and 9.8% coefficient of variation. In conclusion, the functional electromechanical dynamometer is a valid device for measuring isometric strength in the hip abductor muscles. The three assessed positions are reliable, although the supine position with allometric data normalization provided the best results. © 2018 Cerda Vega et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.