Examinando por Autor "Niklander, Sven Eric"
Mostrando 1 - 3 de 3
Resultados por página
Opciones de ordenación
Ítem Effect of ultrasonic activation on dentinalr tubule penetration of Bio-C temp and ultracal XS: A comparative CLSM assessment(Kare Publishing, 2023) Peña-Bengoa, Fernando; Magasich, María Consuelo; Bustamante, Delia; Wastavino, Catalina; Niklander, Sven Eric; Cáceres, CarolinaObjective: The aim of this study was to compare the effect of ultrasonic activation (UA) on tubular penetration between Bio-C Temp and Ultracal XS intracanal medicaments. Methods: Forty single-rooted human premolars were endodontically prepared and divided into 4 experimental groups (n=10): Bio-C Temp, Bio-C Temp+UA, UltraCal XS and UltraCal XS+UA. All medicaments were previously mixed with a specific calcium marker (Fluo-3) and passively injected into the canals. The samples were incubated for 7 days. For each tooth, 1 mm thick sections were obtained from the middle and apical thirds of the canals. The samples were examined by confocal laser scanning microscopy (CLSM) and the depth and area of penetration were determined for each group. The Student t test was used to compare results between groups (p<0.05). Results: UA increased the depth and penetration area of Bio-C Temp and Ultracal XS, showing significant differences in the penetration area of the apical third for Bio-C Temp (p<0.0339). Bio-C Temp presented greater tubular penetration than Ultracal XS, showing significant differences in the depth of penetration in the apical third (p<0.0005), and in the penetration area in the middle (p<0.0016) and apical third (p<0.0339) after UA. Conclusion: UA increases tubular penetration (both depth and area) of Bio-C Temp at the apical third but has no significant effect on Ultracal XS. Bio-C Temp has a greater depth and tubular penetration area than Ultracal XS after UA. © 2023 Kare Publishing. All rights reserved.Ítem Orthopantomography Versus Cone Beam Computed Tomography for the Assessment of the Proximity of Posterior Maxillary Apexes with the Maxillary Sinus: A Cross-sectional Study(Bentham Science Publishers, 2024) Rodriguez, Macarena; Marshall, Maureen; Godoy, Constanza; Richa, Roxana; Niklander, Sven EricBackground: The lack of knowledge of the relation of the maxillary sinus with the apexes of maxillary posterior teeth can lead to important complications during common dental procedures. This can be avoided using different imaging techniques, such as orthopantomography (OPG) and cone beam computed tomography (CBCT). The present study aims to compare the performance of OPG with CBCT in measuring the vertical distance of the apexes of posterior-superior teeth to the maxillary sinus. Methods: This study corresponded to a cross-sectional study. OPGs and CBCT scans were obtained from the same individuals, and the qualitative and quantitative vertical distance of the apexes in relation to the maxillary sinus was categorized and measured in mm. Results: A total of 28 pairs of OPGs and CBCT scans from the same patients were obtained. About 381 roots were analysed, which included 89 upper first premolars, 51 upper second premolars, 115 upper first molars, and 126 upper second molars. Projection/protrusion was observed with more frequency in molars, specially 1º molars in both OPG (n= 75, 65.2%) and CBCT (n= 31, 27%); however, 106 more cases (27.9%) were classified as projected in the OPG compared to CBCT (p < 0.05). When comparing the performance of the OPG and CBTC for analysing all roots qualitatively, there was a 57.8% agreement between both techniques. This difference was statistically significant (p <0.0001). Statistically significant differences were also observed when comparing the millimetric differences. Conclusion: This study showed that OPG is not an accurate technique to observe the relationship between the maxillary sinus and the apexes of the upper posterior teeth. In those cases where precision is required when performing dental procedures in this area, CBCT should be used. When not available, the clinicians should be aware of the limitations of the OPG and add other complementary techniques. © 2024 The Author(s). Published by Bentham Science Publisher.Ítem Salivary Biomarkers for Oral Cancer Detection: An Exploratory Systematic Review(MDPI, 2024-03-05) Bastías, Daniel; Maturana, Alejandro; Marín, Constanza; Martínez, René; Niklander, Sven EricDifferent efforts have been made to find better and less invasive methods for the diagnosis and prediction of oral cancer, such as the study of saliva as a source of biomarkers. The aim of this study was to perform a scoping review about salivary molecules that have been assessed as possible biomarkers for the diagnosis of oral squamous cell carcinoma (OSCC). A search was conducted using EBSCO, PubMed (MEDLINE), Scopus, and Web of Science. The research question was as follows: which molecules present in saliva have utility to be used as biomarkers for the early detection of oral cancer? Sixty-two studies were included. Over 100 molecules were assessed. Most of the markers were oriented towards the early diagnosis of OSCC and were classified based on their ability for detecting OSCC and oral potentially malignant disorders (OPMDs), OSCC outcome prediction, and the prediction of the malignant transformation of OPMDs. TNF-α, IL-1β, IL-6 IL-8, LDH, and MMP-9 were the most studied, with almost all studies reporting high sensitivity and specificity values. TNF-α, IL-1β, IL-6 IL-8, LDH, and MMP-9 are the most promising salivary biomarkers. However, more studies with larger cohorts are needed before translating the use of these biomarkers to clinical settings.