A Hybrid FCS-MPC With Low and Fixed Switching Frequency Without Steady-State Error Applied to a Grid-Connected CHB Inverter

dc.contributor.authorRAMÍREZ, ROBERTO O.
dc.contributor.authorBAIER, CARLOS R.
dc.contributor.authorVILLARROEL, FELIPE
dc.contributor.authorESPINOZA, JOSÉ R.
dc.contributor.authorPOU, JOSEP
dc.contributor.authorRODRÍGUEZ, JOSÉ
dc.date.accessioned2021-11-22T14:24:29Z
dc.date.available2021-11-22T14:24:29Z
dc.date.issued2020-12
dc.description.abstractThis paper presents a new finite control set model predictive control strategy that, contrary to conventional approaches, achieves (i) zero steady-state error in the converter's AC current, and (ii) both fixed and lower harmonic spectrum, similar to that achieved by pulse width modulation based control schemes. These characteristics are attractive for medium and high voltage applications where high dv/dt is prohibitive and reduced switching losses are a must, or in applications that use passive filters and where a spread harmonic spectrum can cause resonances. The proposed strategy achieves dynamic results similar to those of conventional predictive control and a steady-state performance similar to that of a modulated control strategy. To do so, the strategy utilizes a modulated integral action to incorporate an input restriction into a conventional predictive control cost function. A grid-connected cascaded H-Bridge multilevel inverter is used to validate the strategy. Simulated and experimental results in both steady and transient states are presented to verify the proposed strategy's performance in the converter. © 2013 IEEE.es
dc.description.sponsorshipIndexación: Scopuses
dc.identifier.citationIEEE AccessOpen Access Volume 8, Pages 223637 - 2236512020 Article number 9291486es
dc.identifier.issn21693536
dc.identifier.urihttp://repositorio.unab.cl/xmlui/handle/ria/20991
dc.language.isoenes
dc.publisherInstitute of Electrical and Electronics Engineers Inc.es
dc.subjectFCS-MPC; grid connected inverters; predictive control; PWM; spread spectrum; steady-state error; switching frequencyes
dc.titleA Hybrid FCS-MPC With Low and Fixed Switching Frequency Without Steady-State Error Applied to a Grid-Connected CHB Inverteres
dc.typeArtículoes
Archivos
Bloque original
Mostrando 1 - 1 de 1
Cargando...
Miniatura
Nombre:
Roberto-A_Hybrid_FCS-MPC_With_Low_and_Fixed_Switching_Frequency_Without_Steady-State_Error_Applied_to_a_Grid-Connected_CHB_Inverter.pdf
Tamaño:
7.64 MB
Formato:
Adobe Portable Document Format
Descripción:
TEXTO EN INGLES
Bloque de licencias
Mostrando 1 - 1 de 1
No hay miniatura disponible
Nombre:
license.txt
Tamaño:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descripción: