Test–Retest Reliability of Functional Electromechanical Dynamometer on Five Sit-to-Stand Measures in Healthy Young Adults

dc.contributor.authorJerez-Mayorga, Daniel
dc.contributor.authorHuerta-Ojeda, Álvaro
dc.contributor.authorChirosa-Ríos, Luis
dc.contributor.authorGuede-Rojas, Francisco
dc.contributor.authorGuzmán, Iris
dc.contributor.authorIntelangelo, Leonardo
dc.contributor.authora Miranda-Fuentes, Claudia
dc.contributor.authorDelgado-Floody, Pedro
dc.date.accessioned2021-07-09T16:05:44Z
dc.date.available2021-07-09T16:05:44Z
dc.date.issued2021-06
dc.descriptionIndexación: Scopuses
dc.description.abstractBackground: The purpose of this study was to determine the reliability for the strength and movement velocity of the concentric phase from the five Sit-to-Stand (5STS), using three incremental loads measured by a functional electromechanical dynamometer (FEMD) in healthy young adults. Methods: The average and peak strength and velocity values of sixteen healthy adults (mean ± standard deviation (SD): age = 22.81 ± 2.13 years) were recorded at 5, 10 and 15 kg. To evaluate the reliability of FEMD, the intraclass correlation coefficient (ICC), standard error of measurement (SEM) and coefficient of variation (CV) were obtained. Results: Reliability was high for the 10 kg (CV range: 3.70–4.18%, ICC range: 0.95–0.98) and 15 kg conditions (CV range: 1.64–3.02%, ICC: 0.99) at average and peak strength, and reliability was high for the 5 kg (CV range: 1.71–2.84%, ICC range: 0.96–0.99), 10 kg (CV range: 0.74–1.84%, ICC range: 0.99–1.00) and 15 kg conditions (CV range: 0.79–3.11%, ICC range: 0.99–1.00) at average and peak velocity. Conclusions: The findings of this study demonstrate that FEMD is a reliable instrument to measure the average and peak strength and velocity values during the five STS in healthy young adults. © 2021 by the authors. Licensee MDPI, Basel, Switzerland.es
dc.identifier.citationInternational Journal of Environmental Research and Public Health Open Access Volume 18, Issue 131 July 2021 Article number 6829es
dc.identifier.urihttp://repositorio.unab.cl/xmlui/handle/ria/19335
dc.language.isoenes
dc.publisherMDPI AGes
dc.titleTest–Retest Reliability of Functional Electromechanical Dynamometer on Five Sit-to-Stand Measures in Healthy Young Adultses
dc.typeArtículoes
Archivos
Bloque original
Mostrando 1 - 1 de 1
Cargando...
Miniatura
Nombre:
Daniel_Test-Retest Reliabulity of Functional.pdf
Tamaño:
1.77 MB
Formato:
Adobe Portable Document Format
Descripción:
TEXTO COMPLETO EN INGLÉS
Bloque de licencias
Mostrando 1 - 1 de 1
No hay miniatura disponible
Nombre:
license.txt
Tamaño:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descripción: