Bayesian inference of spectrometric data and validation with numerical simulations of plasma sheath diagnostics of a plasma focus discharge

dc.contributor.authorAvaria, G.
dc.contributor.authorClausse, A.
dc.contributor.authorDavis, S.
dc.contributor.authorPavez, C.
dc.contributor.authorVillalba, N.
dc.contributor.authorCuadrado, O.
dc.contributor.authorMoreno, J.
dc.contributor.authorRuiz, M.
dc.contributor.authorSoto, L.
dc.date.accessioned2022-10-05T14:41:44Z
dc.date.available2022-10-05T14:41:44Z
dc.date.issued2022-09
dc.descriptionIndexación: Scopus.es
dc.description.abstractPlasma Foci are pulsed coaxial discharges with numerous radiation applications and interesting scientific phenomena. Although the physics answered much of the processes involved in these discharges, many related fundamental questions still remains doggedly unresolved. One of the obstacles to deeper knowledge is the scarcity of reliable experimental data. This work presents an elaborate experimental assessment of the electron density in the rundown phase of a 400 J Plasma Focus operating with hydrogen. The rundown of the plasma sheath is basically a hypersonic shock wave between two coaxial electrodes accelerated by the Lorentz force, and it is important to control the pinch formation. The electron density of the passing sheath is measured by means of the Stark broadened hydrogen alpha emission with spatial and temporal resolution. The experimental data is post-processed using Bayesian posterior probability assessment. The results are conflated with the numerical model CShock to construe an educated explanation of the sheath behavior during the rundown. In particular, it is possible to reckon the formation of a toroidal instability reported in previous experiments, and to estimate the plasma sheath temperature (4–20 eV) and velocity (62.5 km/s) at this stage.es
dc.description.urihttps://www-nature-com.recursosbiblioteca.unab.cl/articles/s41598-022-19764-7
dc.identifier.citationScientific Reports, Volume 12, Issue 1, December 2022, Article number 15601es
dc.identifier.doi10.1038/s41598-022-19764-7
dc.identifier.issn2045-2322
dc.identifier.urihttps://repositorio.unab.cl/xmlui/handle/ria/24177
dc.language.isoenes
dc.publisherNature Researches
dc.rights.licenseAttribution 4.0 International (CC BY 4.0)
dc.rights.urihttps://www-nature-com.recursosbiblioteca.unab.cl/srep/open-access
dc.subjectplasmaes
dc.subjectBayesian inferencees
dc.subjectspectrometric dataes
dc.subjectplasma sheathes
dc.subjectdiagnosticses
dc.subjectplasma focus dischargees
dc.subjectPlasma Focuses
dc.titleBayesian inference of spectrometric data and validation with numerical simulations of plasma sheath diagnostics of a plasma focus dischargees
dc.typeArtículoes
Archivos
Bloque original
Mostrando 1 - 1 de 1
Cargando...
Miniatura
Nombre:
Avaria_Bayesian inference of spectrometric data and validation with numerical simulations of plasma sheath diagnostics of a plasma focus discharge.pdf
Tamaño:
3.45 MB
Formato:
Adobe Portable Document Format
Descripción:
TEXTO COMPLETO EN INGLES
Bloque de licencias
Mostrando 1 - 1 de 1
No hay miniatura disponible
Nombre:
license.txt
Tamaño:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descripción: