Test–Retest Reliability of the Functional Electromechanical Dynamometer for Squat Exercise

dc.contributor.authordel-Cuerpo, Indya
dc.contributor.authorJerez-Mayorga, Daniel
dc.contributor.authorDelgado-Floody, Pedro
dc.contributor.authorMorenas-Aguilar, María Dolores
dc.contributor.authorChirosa-Ríos, Luis Javier
dc.date.accessioned2025-03-11T13:13:41Z
dc.date.available2025-03-11T13:13:41Z
dc.date.issued2023-01
dc.descriptionIndexación: Scopus
dc.description.abstractBackground: the main objective of this study was to evaluate the test-retest reliability of two different functional electromechanical dynamometry (FEMD)-controlled squat training protocols. Methods: twenty-eight healthy young adults volunteered to participate in this study. They attended the laboratory on four different days and performed four sessions: two of three sets of 12 repetitions at 75% 1RM and two of three sets of 30 repetitions at 50% 1RM. The range of movement (ROM), mean dynamic strength (MDS), peak dynamic strength (PDS), mean velocity (MV), peak velocity (PV), mean potency (MP), peak potency (PP), work (W), and impulse (I) were recorded. To evaluate the reliability of FEMD, the intraclass correlation coefficient (ICC), standard error of measurement (SEM), and coefficient of variation (CV) were obtained. Results: reliability was very high for ROM (CV: 3.72%, ICC: 0.95), MDS (CV: 1.09%, ICC: 1.00), PDS (CV: 1.97%, ICC: 1.00), and W (CV: 4.69%, ICC: 1.00) conditions at 50% 1RM and for ROM (CV: 3.90%, ICC: 0.95), MDS (CV: 0.52, ICC: 1.00), PDS (CV: 1.49%, ICC: 0.98), and W (CV: 4.14%, ICC: 1.00) conditions at 75% 1RM and high for the rest of variables at 50 and 75% 1RM. Conclusions: this study demonstrates that FEMD is a reliable instrument to measure ROM, MDS, PDS, MV, PV, PV, MP, MP, W, and I during both squat protocols (50 and 75% 1RM) in healthy young adults. © 2023 by the authors.
dc.description.urihttps://www.mdpi.com/1660-4601/20/2/1289
dc.identifier.citationInternational Journal of Environmental Research and Public Health. Volume 20, Issue 2. January 2023. Article number 1289
dc.identifier.doi10.3390/ijerph20021289
dc.identifier.issn1661-7827
dc.identifier.urihttps://repositorio.unab.cl/handle/ria/63729
dc.language.isoen
dc.publisherMDPI
dc.rights.licenseAttribution 4.0 International Deed (CC BY 4.0)
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/
dc.subjectDynamometer
dc.subjectIsokinetic
dc.subjectMuscle Strength
dc.subjectReproducibility
dc.titleTest–Retest Reliability of the Functional Electromechanical Dynamometer for Squat Exercise
dc.typeArtículo
Archivos
Bloque original
Mostrando 1 - 1 de 1
No hay miniatura disponible
Nombre:
ijerph-20-01289-v3.pdf
Tamaño:
4.29 MB
Formato:
Adobe Portable Document Format
Descripción:
TEXTO COMPLETO EN INGLES
Bloque de licencias
Mostrando 1 - 1 de 1
No hay miniatura disponible
Nombre:
license.txt
Tamaño:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descripción: