Resistencia ante fuerzas traccionales de postes de fibra de vidrio individualizados con resina compuesta versus individualizados con cerómero

dc.contributor.advisorVargas Bignotti, Pablo
dc.contributor.advisorValdivia Osorio, José
dc.contributor.authorOrellana Conget, María José
dc.contributor.editorFacultad de Odontología
dc.date.accessioned2019-06-26T22:11:18Z
dc.date.available2019-06-26T22:11:18Z
dc.date.issued2012
dc.descriptionTesis (Cirujano Dentista, Especialización en Clínica Integral del Adulto)es_ES
dc.description.abstractOBJETIVOS: Evaluar la resistencia traccional de postes de fibra de vidrio individualizados con resina compuesta y con cerómero para comparar ambos resultados e identificar el tipo de falla adhesiva producida en cada muestra. MÉTODOS: Se realizó un estudio de tipo experimental in vitre. Se recolectaron 30 piezas dentarias humanas (caninos y premolares unirradiculares) a los cuales se les realizó un tratamiento endodóntico para posteriormente decoronar las piezas a 2 mm por sobre el LAC y desobturar 10 mm en cada una. El diámetro de los conductos fue igualado con la fresa piloto para postes de fibra de vidrio Relyx Fiber Post® No 1. La muestra fue dividida en 2 grupos. El grupo 1 consistió en 15 piezas a las cuales se les individualizaron postes en clínica con resina compuesta. El grupo 2 o "grupo experimental" consistió en 15 piezas con postes individualizados con cerómero en el laboratorio. Ambos grupos de postes fueron cementados con cemento de resina de autopolimerización Relyx U 1 00® 3M ESPE. Todos los especímenes fueron sometidos a fuerzas traccionales mediante la máquina lnstron modelo 4411, luego de 72 hrs. de cementados los postes hasta lograr la descementación de éstos. Obtenidos y tabulados los resultados, se les realizó un análisis estadístico mediante el ANOVA y Test de Tukey, considerando significativo un p<0.05. RESULTADOS: . P = 0.496, por lo tanto no existe diferencia significativa entre la resistencia traccional promedio del grupo 1 (5. 773 MPa) en comparación con el grupo 2 (5.314 MPa). El tipo de falla producida más prevalente fue la de tipo "adhesiva al poste" en un 53.3% para el grupo 1 y en un 67.7% para el grupo 2, siendo la de tipo "adhesiva al diente" la de menor ocurrencia, en un 13.33% para ambos grupos. CONCLUSIONES: La resistencia a la tracción de un poste individualizado con resina compuesta en clínica es similar a la obtenida con un poste individualizado con cerómero en laboratorio, sin mostrar diferencia estadísticamente significativa para este estudio.es_ES
dc.description.abstractOBJECTIVES: Evaluate the resistance to tensile forces of glass fiber post individualized with ceromer and glass fiber post individualized with resin composite in order to compare both results. ldentify the type of adhesive failure produced in each sample and determine each percentage of occurrence. METHODS: An experimental in vitro study was performed. For this, 30 tooth were collected (canines and premolars) and were submitted to endodontic treatments with gutapercha. Subsequently, there crown were cut 2 millimeters up their amelocemental limit in order to ream 10 mm. in each root structure. The diameter of the root canal was standardize by the pilot bur included in Relyx Fiber Post® kit No 1. The sample was divided in 2 groups. The group 1 or "control group" consisted in 15 teeth with glass fiber posts individualized with resin composite, and group 2 or "experimental group" was individualized with ceromer Artglass® in the laboratory. Both groups of posts were cemented with autocure resin cement, self-adhesive such as Relyx U100® 3M ESPE. Seventy two hours later, the entire sample was submitted to tensile forces by the lnstron machine to produce the de-bond of the posts. Once the results were sorted in an excel spreadsheet, an statistical analysis was apply by the ANOVA and Tukey Test, with a P < o = 0.05 in order to consider significant differences. RESUL TS: P = 0.496, therefore it doesn't exist significant differences between the average of tensile strength of both groups (Group 1 = 5.773 MPa, Group 2= 5.314 MPa). The most produced type of failure was the "adhesive to the post" in a 53.3% for group 1 and 67.7% for group 2, being the "adhesive to the teeth" type the failure that less occurs in a 13.33% in both groups. CONCLUSIONS: The tensile resistance of a glass fiber post individualized with resin composite in clinic is similar to the resistance obtained with a glass fiber post individualized with ceromer in the laboratory, without showing significant statistic differences in this study.EN
dc.identifier.urihttp://repositorio.unab.cl/xmlui/handle/ria/9392
dc.language.isoeses_ES
dc.publisherUniversidad Andrés Belloes_ES
dc.subjectMateriales Dentales.es_ES
dc.subjectFibras de Vidrio.es_ES
dc.titleResistencia ante fuerzas traccionales de postes de fibra de vidrio individualizados con resina compuesta versus individualizados con cerómeroes_ES
dc.typeTesises_ES
Archivos
Bloque original
Mostrando 1 - 1 de 1
No hay miniatura disponible
Nombre:
a88401_Orellana_M_Resistencia_ante_fuerzas_traccionales_de_2013.pdf
Tamaño:
25.54 MB
Formato:
Adobe Portable Document Format
Descripción:
TEXTO COMPLETO ESPAÑOL
Bloque de licencias
Mostrando 1 - 1 de 1
No hay miniatura disponible
Nombre:
license.txt
Tamaño:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descripción: