ComparaciĆ³n de resistencia adhesiva "push-out" entre postes cementados con adhesivo autograbante y grabado convencional

dc.contributor.advisorVildĆ³sola Grez, Patricio
dc.contributor.authorAstudillo GonzƔlez, Claudio
dc.contributor.editorFacultad de OdontologĆ­a
dc.date.accessioned2019-08-26T21:36:49Z
dc.date.available2019-08-26T21:36:49Z
dc.date.issued2013
dc.descriptionTesis (Cirujano Dentista, EspecializaciĆ³n en ClĆ­nica Integral del Adulto)es
dc.description.abstractEl fracaso mĆ”s comĆŗn en la rehabilitaciĆ³n de una pieza tratada endodĆ³nticamente mediante poste de fibra y reconstrucciĆ³n coronaria es la descementaciĆ³n del poste, probablemente debido a una adhesiĆ³n deficiente entre poste, medio cementante y diente. Actualmente la cementaciĆ³n y adhesiĆ³n intradicular es uno de los temas mĆ”s investigados y con mayor controversia debido a los mĆŗltiples sistemas existentes en el mercado, dentro de los cuales el sistema autograbante ha ganado terreno con una escasa evidencia en cuanto a su comportamiento clĆ­nico. La prueba push-out es uno de los test in vitro el cual evalĆŗa uno de los aspectos clĆ­nicos como es la resistencia adhesiva, por eso el objetivo de este estudio fue comparar in vitro que "existe diferencia significativa, dada por un mayor valor de resistencia al "pushout", entre postes de fibra de vidrio cementados mediante el uso de adhesivo Single Bond 2Ā®, sobre aquellos donde se usarĆ” cemento adhesivo Single Bond UniversalĀ®". Se recolectaron 20 piezas unirradiculares, que fueron divididas en 2 grupos. Grupo SB: poste de fibra cementado con adhesivo Single Bond 2Ā® (Grabado convencional) y RelyX AreĀ® (3M ESPE). Grupo SBU: poste de fibra cementado con RelyX Are aplicando adhesivo Single Bond UniversalĀ® (3M ESPE). Luego de 48 horas, las piezas dentarias fueron seccionadas en el tercio cervical y medio dando un total de 40 muestras. Se realizĆ³ la prueba de "push-out' en la maquina Tinius Olsen H5K-S. Los resultados fueron expresados en megapascales (Mpa), y se aplicĆ³ el anĆ”lisis descriptivo correspondiente, donde se obtuvo un promedio y desviaciĆ³n estĆ”ndar (DSĀ±) para SB de 13.89 (Ā±1.01) y para SBU de 11.85 (Ā±1.19); por otra parte, y cupando un nivel de significancia del 95% se realizĆ³ la prueba de t-student que dio como resultado que hay diferencia significativa entre cada uno de los grupos estudiados (p<0.05). ConclusiĆ³n: Hay diferencia significativa en el valor de resistencia entre SB y SU teniendo un mayor valor el grupo SB.es
dc.description.abstractThe most common failure in the rehabilitation of endodontically treated piece by fiber post and coronary reconstruction is the debonding of the post, probably due to poor adhesion between post, cementing medium and tooth. Currently intradicular cementation and bonding is one of the most investigated and most controversia! because of multiple systems on the market, like self-etching system, has gained ground with little evidence regarding their clinical behavior. The push-out test is one of the in vitro test which evaluates clinical aspect as adhesive strength, therefore the purpose of this study was to compare in vitro "Significant difference, given by higher resistance value the push-out between fiberglass post cemented with Single Bond 2 Ā® and fiberglass post cemented with Single Bond Universal Ā®". 20 monoradicular pieces were collected, which were divided into 2 groups: SB Group: fiber post cemented with adhesive Single Bond 2 Ā® (conventional Etching) and RelyX Are Ā® (3M ESPE); SBU Group: fiber post cemented with RelyX Are applying Single Bond Universal Ā® (3M ESPE). After 48 hours, the teeth were sectioned at the Ā· third cervical and medium giving a total of 40 samples. Test was performed "push-out" in the Tinius Olsen H5K-S machine. The results were expressed in megapascals (MPa), and applied the corresponding descriptive analysis, where it was found an average and standard deviation (Ā± SD) for SB of 13.89 (Ā± 1.01) and 11.85 SBU (Ā± 1.19), on the other hand, and occupying a significance level of 95% was done on t-student test which resulted in that no significant difference between each of the groups (p <.05). Conclusion: There is significant difference in the resistance value between SB and SBU having a higher value SB group.
dc.identifier.urihttp://repositorio.unab.cl/xmlui/handle/ria/9915
dc.language.isoeses
dc.publisherUniversidad AndrƩs Belloes
dc.subjectMateriales Dentaleses
dc.subjectCementaciĆ³nes
dc.subjectChilees
dc.titleComparaciĆ³n de resistencia adhesiva "push-out" entre postes cementados con adhesivo autograbante y grabado convencionales
dc.typeTesises
Archivos
Bloque original
Mostrando 1 - 1 de 1
No hay miniatura disponible
Nombre:
a105770_Astudillo_C_Comparacion_de_resistencia_adhesiva_push_2013.pdf
TamaƱo:
28.29 MB
Formato:
Adobe Portable Document Format
DescripciĆ³n:
TEXTO COMPLETO EN ESPAƑOL
Bloque de licencias
Mostrando 1 - 1 de 1
No hay miniatura disponible
Nombre:
license.txt
TamaƱo:
1.71 KB
Formato:
Item-specific license agreed upon to submission
DescripciĆ³n: