Experimental measurements of high-energy photons in X-rays pulses emitted from a hundred joules plasma focus device and its interpretations

dc.contributor.authorJain, J.
dc.contributor.authorMoreno, J.
dc.contributor.authorDavis, S.
dc.contributor.authorBora, B.
dc.contributor.authorPavez, C.
dc.contributor.authorAvaria, G,
dc.contributor.authorSoto, L.
dc.date.accessioned2024-09-11T17:58:14Z
dc.date.available2024-09-11T17:58:14Z
dc.date.issued2020-03
dc.descriptionTEXTO COMPLETO EN INGLÉS
dc.description.abstractIn the present work, efforts are made to identify the presence of high energy photons in X-rays pulses, emitted from a hundred joules plasma focus device, PF-400J. Two different experiments were carried out, with the insertion of a lead piece inside the hollow anode of PF-400J and without insertion of the lead piece. A pair of two photomultiplier tubes (PMTs) was mounted in the axial direction and a similar pair of PMTs was mounted in the radial direction, simultaneously. After establishing a correlation between two PMTs in each pair, one of the PMTs in both directions was blocked by a rectangular slab of the lead of thickness ~17 mm. Linear attenuation coefficient (LAC) of lead was estimated using the PMTs signals. Later, the X-rays energies were interpolated for the estimated LAC values in both cases, with and without insertion of lead piece inside the hollow anode. Interpolated energies reveal the presence of 0.55–0.85 MeV photons in the X-rays pulses in the axial direction, while, in radial direction ranges 0.4–0.9 MeV, for the case without lead inserted inside the hollow anode. Insertion of the lead inside the hollow anode does not change the X-rays energies significantly, nonetheless, it increases X-rays repetition rate per hundred discharges. The presence of high energy photons in the X-rays pulses indicates the existence of relativistic electrons. To explain it, induced electric and magnetic fields were estimated using generalized Ohm’s law. We conclude that the electron acceleration mechanisms might not be the same in the axial and radial directions.
dc.description.urihttps://www-sciencedirect-com.recursosbiblioteca.unab.cl/science/article/pii/S221137971932875X
dc.identifier.citationResults in Physics,Volume 16 , March 2020, 102915
dc.identifier.doihttps://doi.org/10.1016/j.rinp.2019.102915
dc.identifier.issn2211-3797
dc.identifier.urihttps://repositorio.unab.cl/handle/ria/60101
dc.language.isoen
dc.publisherElsevier
dc.rights.licenseAttribution-NonCommercial-NoDerivatives 4.0 International
dc.subjectPF-400J
dc.subjectLinear attenuation coefficient
dc.subjectX-rays energy
dc.subjectRelativistic electrons
dc.titleExperimental measurements of high-energy photons in X-rays pulses emitted from a hundred joules plasma focus device and its interpretations
dc.typeArtículo
Archivos
Bloque original
Mostrando 1 - 1 de 1
No hay miniatura disponible
Nombre:
Jain_Experimental measurements of high-energy photons in X-rays pulses emitted.pdf
Tamaño:
2.72 MB
Formato:
Adobe Portable Document Format
Bloque de licencias
Mostrando 1 - 1 de 1
No hay miniatura disponible
Nombre:
license.txt
Tamaño:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descripción: