Comparación del comportamiento clínico a 6 meses entre dos resinas bulk-fill y una resina convencional en lesiones cervicales no cariosas
dc.contributor.advisor | Nakouzi Momares, Jorge | |
dc.contributor.author | Reyes Valencia, Alexandra | |
dc.contributor.author | Reyes García, Jenifer | |
dc.contributor.editor | Facultad de Odontología | |
dc.contributor.editor | Escuela de Odontología | |
dc.date.accessioned | 2018-03-23T19:01:45Z | |
dc.date.available | 2018-03-23T19:01:45Z | |
dc.date.issued | 2017 | |
dc.description | Tesis (Cirujano Dentista) | es_ES |
dc.description.abstract | Objetivo: Evaluar el comportamiento clínico a 6 meses de dos resinas Bulk-Fill (RBK), según criterios FDI en lesiones cervicales. Materiales y métodos: 51 pacientes con 3 lesiones cervicales fueron distribuidos aleatoriamente como Grupo TN: 51 restauraciones con Tetric-N-Ceram Bulk-Fill, Grupo FBK: 51 restauraciones con Filtek Bulk-Fill y Grupo control Z350: 51 restauraciones con Filtek Z350XT. El proceso de restauración fue con aislamiento absoluto. Se realizó acondicionamiento con ácido ortofosfórico al 37% por 20 segundos en esmalte, se lavó, secó y se aplicó adhesivo Single Bond Universal para Z350 y FBK, y Tetric N-Bond Universal para TN. En TN y FBK se aplicó un incremento hasta 4mm y en Z350 se aplicó incrementos hasta 2 mm. Un operador calibrado (Kappa>0.8) evaluó las restauraciones a los 6 meses mediante criterios FDI (Tinción marginal (TM), fractura y retención (FR), adaptación marginal (AM), sensibilidad postoperatoria (S), caries). Para la comparación entre baseline-6 meses se utilizó Wilcoxon y la comparación de los 3 grupos a 6 meses test Kruskal-Wallis (significancia de 95%). Resultados: Al control asistieron 46 pacientes (n= 138). En el parámetro TM fue evaluado 2 solo un 8,7% en Z350, 2,2% en FBK, y 2,2% en TN. Para AM fue 4,3% en Z350, 2,2% en FBK, 0% en TN. Para S fue 2.2% en Z350 y 4,3 FBK. Para caries y FR el 100% fue evaluado con 1. No hubo diferencias estadísticamente significativas (p>0.05) entre los 3 grupos. Conclusión: No existe diferencia significativa en el comportamiento clínico a 6 meses entre los 3 grupos de resinas en todos los parámetros según criterios FDI. | es_ES |
dc.description.abstract | Objetive: To evaluate the clinical performance at 6 months of two Bulk-Fill resins (RBK), according to FDI criteria in cervical lesions. Materials and method: 51 patients with 3 cervical lesions were distributed randomly as TN Group: 51 restorations with Tetric-N-Ceram Bulk-Fill, FBK Group: 51 restorations with Filtek Bulk-Fill and Control Group Z350: 51 restorations with Filtek Z350XT. The restoration process was with absolute isolation. Conditioning was carried out with 37% orthophosphoric acid for 20 seconds in enamel, washed, dried and applied Single Bond Universal adhesive for Z350 and FBK, and Tetric N-Bond Universal for TN. In TN and FBK an increase was applied up to 4mm and in Z350 increments up to 2mm were applied. A calibrated operator (Kappa> 0.8) evaluated the restorations at 6 months using FDI criteria (marginal staining (TM), fracture and retention (FR), marginal adaptation (AD), postoperative sensitivity (S), caries). For comparison between baseline-6 months Wilcoxon was used and the comparison of the 3 groups to 6 months Kruskal-Wallis test (95% significance). Results: The control was attended by 46 patients (n = 138). In the TM parameter, only 2.87% were evaluated in Z350, 2.2% in FBK, and 2.2% in TN. For AM it was 4.3% in Z350, 2.2% in FBK, 0% in TN. For S it was 2.2% in Z350 and 4.3% FBK. For caries and FR 100% was evaluated with 1. There was no significant difference between the groups (p >0,05). Conclusion: The two Bulk-Fill composite-resin cervical restorations were no had significant difference in clinical performance compared with the nanofilled control restorations evaluated by FDI criteria after 6 months. | |
dc.identifier.uri | http://repositorio.unab.cl/xmlui/handle/ria/5508 | |
dc.language.iso | es | es_ES |
dc.publisher | Universidad Andrés Bello | es_ES |
dc.subject | Restauración Dental | es_ES |
dc.subject | Resinas Compuestas | es_ES |
dc.title | Comparación del comportamiento clínico a 6 meses entre dos resinas bulk-fill y una resina convencional en lesiones cervicales no cariosas | es_ES |
dc.type | Tesis | es_ES |
Archivos
Bloque original
1 - 1 de 1
Cargando...
- Nombre:
- a120841_Reyes_A_Comparacion_del_comportamiento_clinico_a_2017_tesis.pdf
- Tamaño:
- 1.15 MB
- Formato:
- Adobe Portable Document Format
- Descripción:
- TEXTO COMPLETO EN ESPAÑOL
Bloque de licencias
1 - 1 de 1
No hay miniatura disponible
- Nombre:
- license.txt
- Tamaño:
- 1.71 KB
- Formato:
- Item-specific license agreed upon to submission
- Descripción: