Pulsed x-rays dose measurements from a hundred joules plasma focus device

dc.contributor.authorJain, J.
dc.contributor.authorMoreno, J.
dc.contributor.authorAvila, R.E.
dc.contributor.authorAvaria, G.
dc.contributor.authorPavez, C.
dc.contributor.authorBora, B.
dc.contributor.authorDavis, S.
dc.contributor.authorSoto, L.
dc.date.accessioned2019-11-08T13:39:30Z
dc.date.available2019-11-08T13:39:30Z
dc.date.issued2018-06
dc.descriptionIndexación: Scopus.es
dc.description.abstractPresent work is aimed to perform dosimetric measurements to characterize dosis obtained from pulsed x-rays emitted from a hundred joules plasma focus device PF-400J using thermoluminescent dosimeters (TLD-100). Two dosimeter arrays (containing 21 dosimeters in each) were used. One of the arrays was kept inside the PF-400J vacuum chamber and other outside the vacuum chamber, simultaneously. It was found that dosis obtained from the inside array (∼200.7 mGy) were hundred times larger than the outside array (∼1.1 mGy) for hundred pulses of x-rays. Later, the vacuum window of PF-400J, which was made of 1 mm aluminum, was replaced by a plastic window and a similar dosimeter array was kept outside the chamber over the plastic window. With this arrangement, the obtained doses (100 pulses of x-rays) were of the same order of magnitude (∼106 mGy) as it was inside the vacuum chamber. Later, a lead piece was inserted inside the hollow anode of PF-400J, which increased dose (∼250 mGy) per hundred pulses of x-ray outside the vacuum chamber using plastic vacuum window. Our results suggest that PF-400J could be a useful device to study low dose pulsed radiation effects on cancer cell lines in in vitro experiments. © Published under licence by IOP Publishing Ltd.es
dc.description.abstractThe work is supported by grant ACT-1115, CONICYT, Chile.
dc.description.urihttps://iopscience.iop.org/article/10.1088/1742-6596/1043/1/012048
dc.identifier.citationJournal of Physics: Conference Series, 1043(1), art. no. 012048es
dc.identifier.issn1742-6588
dc.identifier.otherDOI: 10.1088/1742-6596/1043/1/012048
dc.identifier.urihttp://repositorio.unab.cl/xmlui/handle/ria/10616
dc.language.isoenes
dc.publisherInstitute of Physics Publishinges
dc.subjectCell culturees
dc.subjectDosimeterses
dc.subjectDosimetryes
dc.subjectPlasma deviceses
dc.subjectRadiation effectses
dc.subjectWindowses
dc.titlePulsed x-rays dose measurements from a hundred joules plasma focus devicees
dc.typeArtículoes
Archivos
Bloque original
Mostrando 1 - 1 de 1
Cargando...
Miniatura
Nombre:
Jain_Pulsed_x-rays.pdf
Tamaño:
459.19 KB
Formato:
Adobe Portable Document Format
Descripción:
TEXTO COMPLETO EN INGLES
Bloque de licencias
Mostrando 1 - 1 de 1
No hay miniatura disponible
Nombre:
license.txt
Tamaño:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descripción: