Pulsed x-rays dose measurements from a hundred joules plasma focus device
dc.contributor.author | Jain, J. | |
dc.contributor.author | Moreno, J. | |
dc.contributor.author | Avila, R.E. | |
dc.contributor.author | Avaria, G. | |
dc.contributor.author | Pavez, C. | |
dc.contributor.author | Bora, B. | |
dc.contributor.author | Davis, S. | |
dc.contributor.author | Soto, L. | |
dc.date.accessioned | 2019-11-08T13:39:30Z | |
dc.date.available | 2019-11-08T13:39:30Z | |
dc.date.issued | 2018-06 | |
dc.description | Indexación: Scopus. | es |
dc.description.abstract | Present work is aimed to perform dosimetric measurements to characterize dosis obtained from pulsed x-rays emitted from a hundred joules plasma focus device PF-400J using thermoluminescent dosimeters (TLD-100). Two dosimeter arrays (containing 21 dosimeters in each) were used. One of the arrays was kept inside the PF-400J vacuum chamber and other outside the vacuum chamber, simultaneously. It was found that dosis obtained from the inside array (∼200.7 mGy) were hundred times larger than the outside array (∼1.1 mGy) for hundred pulses of x-rays. Later, the vacuum window of PF-400J, which was made of 1 mm aluminum, was replaced by a plastic window and a similar dosimeter array was kept outside the chamber over the plastic window. With this arrangement, the obtained doses (100 pulses of x-rays) were of the same order of magnitude (∼106 mGy) as it was inside the vacuum chamber. Later, a lead piece was inserted inside the hollow anode of PF-400J, which increased dose (∼250 mGy) per hundred pulses of x-ray outside the vacuum chamber using plastic vacuum window. Our results suggest that PF-400J could be a useful device to study low dose pulsed radiation effects on cancer cell lines in in vitro experiments. © Published under licence by IOP Publishing Ltd. | es |
dc.description.abstract | The work is supported by grant ACT-1115, CONICYT, Chile. | |
dc.description.uri | https://iopscience.iop.org/article/10.1088/1742-6596/1043/1/012048 | |
dc.identifier.citation | Journal of Physics: Conference Series, 1043(1), art. no. 012048 | es |
dc.identifier.issn | 1742-6588 | |
dc.identifier.other | DOI: 10.1088/1742-6596/1043/1/012048 | |
dc.identifier.uri | http://repositorio.unab.cl/xmlui/handle/ria/10616 | |
dc.language.iso | en | es |
dc.publisher | Institute of Physics Publishing | es |
dc.subject | Cell culture | es |
dc.subject | Dosimeters | es |
dc.subject | Dosimetry | es |
dc.subject | Plasma devices | es |
dc.subject | Radiation effects | es |
dc.subject | Windows | es |
dc.title | Pulsed x-rays dose measurements from a hundred joules plasma focus device | es |
dc.type | Artículo | es |
Archivos
Bloque original
1 - 1 de 1
Cargando...
- Nombre:
- Jain_Pulsed_x-rays.pdf
- Tamaño:
- 459.19 KB
- Formato:
- Adobe Portable Document Format
- Descripción:
- TEXTO COMPLETO EN INGLES
Bloque de licencias
1 - 1 de 1
No hay miniatura disponible
- Nombre:
- license.txt
- Tamaño:
- 1.71 KB
- Formato:
- Item-specific license agreed upon to submission
- Descripción: