Análisis descriptivo del módulo Belin/Ambrósio Enhanced Ectasia en topografía pentacam

dc.contributor.advisorThenot Silva, Jean Claude
dc.contributor.advisorMehech Hirane, Michel
dc.contributor.authorIllanes González, Sebastián
dc.contributor.authorOlivares Bonilla, Álvaro
dc.contributor.authorRubio Muñoz, Lorena
dc.contributor.editorFacultad de Ciencias de la Salud
dc.contributor.editorEscuela de Tecnología Médica
dc.date.accessioned2017-02-02T19:14:59Z
dc.date.available2017-02-02T19:14:59Z
dc.date.issued2009
dc.descriptionTesis (Tecnólogo Médico, mención en oftalmología)es
dc.description.abstractEl estudio de las córneas candidatas a cirugía refractiva Lasik ó sospechosas de queratocono es de suma importancia en la práctica clínica diaria. Hasta hoy se realizaba analizando la curvatura de la cara anterior corneal, la elevación de las caras anterior y posterior de la córnea, además de un exámen médico el cual incluye la biomicroscopía, entre otros. En la actualidad existe un nuevo módulo para el topógrafo Pentacam, llamado Belin/Ambrósio Enhanced Ectasia, el cual es el primero que realiza un estudio 100% computacional de los datos de la elevación corneal, estudiando el aspecto más importante en las ectasias: La elevación de la cara posterior de la córnea. El objetivo de esta investigación es describir y analizar este nuevo módulo, para llevarlo a cabo se estudiaron 100 ojos, divididos en 5 grupos: 20 ojos emétropes, 20 ojos miopes, 20 ojos hipermétropes, 20 ojos astigmatas y 20 ojos con queratocono. El estudio se realizó de forma retrospectiva, revisando las fichas clínicas de cada paciente, se estudió específicamente el Módulo Belin/Ambrósio Enhanced Ectasia de cada uno de ellos, analizando cada datos que entrega. El estudio demostró que los ojos sin queratocono, entregan resultados normales en todos los puntos analizados, excepto en 2 de ellos: la diferencia de elevación de la cara anterior en el grupo astigmata y la diferencia de elevación de la cara posterior en todos los grupos. En el grupo con queratocono, se encontraron valores menores a los esperados, pero aún así patológicos, excepto en el estudio paquimétrico, en el cual los valores de la distancia ápex-punto más delgado de la córnea resultaron ser normales y el índice de progresión sólo estuvo en el intervalo sospechoso. El exámen demostró ser útil para detectar ectasias precoces y córneas riesgosas para la cirugía refractiva con láser, sin embargo el estudio de la cara posterior de la córnea demostró ser muy sensible.es
dc.description.abstractThe study of the corneas for refractive surgery with laser candidates or keratoconus suspect is of great importance in daily clinical practice. Until today it was realised analyzing the curvature of the corneal anterior face, the elevation of the anterior and posterior faces, besides a medical examination which includes biomicroscopy, among others. At present a new module for Pentacam topographer exists, call Belin/Ambrósio Enhanced Ectasia, which is first that performed a fully computer study of the data of the corneal elevation, studying the most important aspect in ectasias: The corneal posterior elevation. The objective of this investigation is to describe and to analyze this new module, to carry out studied it 100 eyes, divided in 5 groups: 20 emmetropic eyes, 20 myopic eyes, 20 astigmatas eyes, 20 hipermetropyc eyes and 20 eyes with Keratoconus. The study was realised of retrospective form, reviewing the medical records of each patient, studied the Belin/Ambrósio Enhanced Ectasia Module of each of them specifically, analyzing each one of the data that give. The study demonstrated that the eyes without Keratoconus, give normal results in all the points analyzed, except in 2 of them: the difference elevation of the previous face in the astigmata group and the difference elevation of the posterior face in all the groups. In the group with Keratoconus, were smaller values to the awaited ones, but even so pathological, except in the pachymetric study, in which the values of the distance apex-thinnest point of the cornea turned out to be normal and the progression index only was in the suspicious interval. The module demonstrated to be useful to detect early ectasias and eyes risky for the refracting surgery with laser, nevertheless the study of the cornea posterior face is very sensible.
dc.identifier.urihttp://repositorio.unab.cl/xmlui/handle/ria/2858
dc.language.isoeses
dc.publisherUniversidad Andrés Belloes
dc.subjectEnfermedades de la Córneaes
dc.subjectCórnea - Morfologíaes
dc.subjectTopografía corneales
dc.subjectElevación de la cara posterior de la córneaes
dc.subjectMódulo Belin/Ambrósio Enhanced Ectasiaes
dc.subjectEnhanced BFSes
dc.subjectQueratoconoes
dc.subjectMapa de exclusiónes
dc.titleAnálisis descriptivo del módulo Belin/Ambrósio Enhanced Ectasia en topografía pentacames
dc.typeTesises
Archivos
Bloque original
Mostrando 1 - 1 de 1
No hay miniatura disponible
Nombre:
a113700_Illanes_S_Analisis_descriptivo_del_modulo_BelinAmbrosio_2009.pdf
Tamaño:
60.13 MB
Formato:
Adobe Portable Document Format
Descripción:
TEXTO COMPLETO ESPAÑOL
Bloque de licencias
Mostrando 1 - 1 de 1
No hay miniatura disponible
Nombre:
license.txt
Tamaño:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descripción: