CONCORDANCE OF THE VESTIBULAR BONE THICKNESS AT THE LEVEL OF POINT A BETWEEN TELERADIOGRAPHY AND CONE BEAM COMPUTED TOMOGRAPHY

dc.contributor.authorVergara, Carolina
dc.contributor.authorEspinoza, Sebastián
dc.contributor.authorGonzález, Paulina
dc.contributor.authorMartens, Camila
dc.contributor.authorRojas, Patricio
dc.contributor.authorCórdova, Pedro
dc.date.accessioned2024-10-08T22:13:51Z
dc.date.available2024-10-08T22:13:51Z
dc.date.issued2023-04
dc.descriptionIndexación: Scopus
dc.description.abstractObjective: The aim of this study was to determine the concordance of the vestibular bone thickness measured at the level of point A between Teleradiography and Cone Beam Computed Tomography (CBCT). Materials and Methods: This study consisted of a cross-sectional analytical design of concordance that evaluated the teleradiographies and CBCTs of 32 patients. The measurements were performed by three evaluators, specialists in orthodontics. Two of them measured the CBCTs and one evaluated the teleradiographs. The concordance of both tests was determined using the Concordance Correlation Coefficient. Results: When evaluating the value of the vestibular bone thickness at the level of point A between the CBCT and the teleradiography, it was observed that the mean value of the absolute difference between the two was 0.9540.74, 95%CI [0.68–1.22], being statistically significant (p=0.0027). When the concordance between both tests was analyzed, it was observed that it was poor (CCC=0.204 95%CI [0.014–0.394]), although statistically significant (p<0.00001). Conclusions: It was possible to conclude that there is no concordance in the measurement of the vestibular bone thickness at the level of Point A between the Teleradiography and the CBCT. © 2023.
dc.description.urihttps://www.joralres.com/index.php/JOralRes/article/view/joralres.2023.006
dc.identifier.citationJournal of Oral Research. Volume 12, Issue 1, Pages 63 - 74. 4 April 2023
dc.identifier.doi10.17126/joralres.2023.006
dc.identifier.issn0719-2460
dc.identifier.urihttps://repositorio.unab.cl/handle/ria/61134
dc.language.isoen
dc.publisherUniversidad de Concepcion
dc.rights.licenseCC BY 4.0 Attribution 4.0 International Deed
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/
dc.subjectCephalometry
dc.subjectCone-beam Computed Tomography
dc.subjectCross-sectional Studies
dc.subjectIncisor
dc.subjectOrthodontics
dc.subjectPatients
dc.titleCONCORDANCE OF THE VESTIBULAR BONE THICKNESS AT THE LEVEL OF POINT A BETWEEN TELERADIOGRAPHY AND CONE BEAM COMPUTED TOMOGRAPHY
dc.title.alternativeConcordancia del espesor óseo vestibular a nivel del Punto A entre Telerradiografía y Tomografía computarizada de haz cónico
dc.typeArtículo
Archivos
Bloque original
Mostrando 1 - 1 de 1
No hay miniatura disponible
Nombre:
Vergara_CONCORDANCE_OF_THE_VESTIBULAR_BONE_THICKNESS_2023.pdf
Tamaño:
360.17 KB
Formato:
Adobe Portable Document Format
Descripción:
TEXTO COMPLETO EN INGLES
Bloque de licencias
Mostrando 1 - 1 de 1
No hay miniatura disponible
Nombre:
license.txt
Tamaño:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descripción: