Uso de la cinética del consumo de oxígeno para la evaluación de la capacidad cardiorrespiratoria en pacientes con obesidad
dc.contributor.author | Miranda, C. | |
dc.contributor.author | Ibacache, P. | |
dc.contributor.author | Opazo, E. | |
dc.contributor.author | Rojas, J. | |
dc.contributor.author | Cano, M. | |
dc.date.accessioned | 2019-05-28T15:05:59Z | |
dc.date.available | 2019-05-28T15:05:59Z | |
dc.date.issued | 2018-01 | |
dc.description | Indexación: Scopus. | es_ES |
dc.description.abstract | Background: The evaluation of cardiorespiratory fitness (RCC) using maximal or peak oxygen consumption (VO2), requires a high level of effort in obese patients. We propose a method to evaluate RCC using constant and moderate loads, called VO2 kinetics (tau). Aim: To determine the relationship between tau and peak VO2 in patients with obesity. Material and Methods: Forty patients (87% females) aged 37 ± 12 years and with a body mass index (BMI) of 34.6 ± 4.0 kg/m2, were divided into two groups according to the applied workload (0.5 and 0.8 Watts/kg body mass) using a cycle ergometer and Cortex Metalyzer 3b equipment. The protocol was started with 6 minutes at constant load and then increments of 20-25 Watts every two min were made until determination of the peak VO2. Results: The tau value was 51.8 ± 17.6 s, the absolute peak VO2 was 2.0 ± 0.7 L/min and the relative peak VO2 was 26.6 ± 30.0 ml/kg/min. There was a significant difference of tau medians between the group that used 0.5 and 0.8 Watts/kg (p = 0.002) and a significant inverse correlation between the absolute peak VO2 and the tau value for a load of 0.5 Watts/kg (rho = -0.415, p = 0.0327). Conclusions: The higher tau value, the lower the peak VO2 of an obese patient. It is suggested to apply loads of 0.5 Watts/kg for a VO2 kinetics test in obese patients or in subjects who do not wish to carry out higher physiological demands with a non-invasive and low risk procedure. | es_ES |
dc.description.uri | https://scielo.conicyt.cl/scielo.php?script=sci_arttext&pid=S0034-98872018000100015&lng=en&nrm=iso&tlng=en | |
dc.identifier.citation | Revista Medica de Chile, 146(1), pp. 15-21. | es_ES |
dc.identifier.issn | 0034-9887 | |
dc.identifier.other | http://dx.doi.org/10.4067/s0034-98872018000100015 | |
dc.identifier.uri | http://repositorio.unab.cl/xmlui/handle/ria/8917 | |
dc.language.iso | es | es_ES |
dc.publisher | Sociedad Medica de Santiago | es_ES |
dc.subject | Exercise test | es_ES |
dc.subject | Obesity | es_ES |
dc.subject | Oxygen consumption | es_ES |
dc.title | Uso de la cinética del consumo de oxígeno para la evaluación de la capacidad cardiorrespiratoria en pacientes con obesidad | es_ES |
dc.title.alternative | Oxygen uptake kinetics to assess cardiorespiratory fitness in obese patients | es_ES |
dc.type | Artículo | es_ES |
Archivos
Bloque original
1 - 1 de 1
Cargando...
- Nombre:
- Miranda_Uso_de_la_cinetica.pdf
- Tamaño:
- 339.3 KB
- Formato:
- Adobe Portable Document Format
- Descripción:
- TEXTO COMPLETO EN ESPAÑOL
Bloque de licencias
1 - 1 de 1
No hay miniatura disponible
- Nombre:
- license.txt
- Tamaño:
- 1.71 KB
- Formato:
- Item-specific license agreed upon to submission
- Descripción: