Análisis digital del ajuste marginal en rehabilitación sobre implantes

dc.contributor.advisorRathkamp S., Hermann
dc.contributor.authorFukuda K., Patricio
dc.contributor.editorFacultad de Odontología
dc.date.accessioned2019-09-25T13:31:19Z
dc.date.available2019-09-25T13:31:19Z
dc.date.issued2008
dc.descriptionTesis (Cirujano Dentista, Especialización en Clínica Integral del Adulto)es
dc.description.abstractHoy en día la rehabilitación oral con implantes es algo cada vez mas cotidiano, al igual la salida al mercado de nuevos modelos y técnicas con opciones que facilitan o disminuyen los tiempos operatorios para el odontólogo, incluyendo la tendencia a recomendar menos el uso de aleaciones que no poseen gran contenido de materiales preciosos, titanio o cerámicos y se aconseja el uso de técnicas maquinadas por sobre las coladas. Este estudio in vitro realiza una evaluación con la finalidad de demostrar si existen cambios dimensionales al realizar una técnica de colado con aleación de Cromo-Cobalto, y si existen, la realización de una técnica compensatoria de rectificado o afinado para posterior comparación con la muestra control que es de titanio y maquinado. Lascuales se evaluaran por medio de microscopia con fotografía y procesamiento digital para ver los valores de micro-brecha existentes para ver si se pueden obtener valores similares a los de la muestra control. El colado de las estructura demostró cambios dimensionales, que impedían un adecuado ajuste, La rectificación de las superficies de los pilares mejoró el ajuste entre ambas estructuras de manera significativa, se realizaron mediciones en la zona media de las estructuras para lo que se realizo un desgaste de estas, las mediciones obtenidas fueron comparadas con la muestra control donde las muestras obtuvieron valores cercanos al control a excepción de una que se aleja de la tendencia, lo que demuestra que una técnica de colado rigurosa y con rectificación da resultados satisfactorios.es
dc.description.abstractIn these days the oral rehabilitation with implants is something more and more common in the the same way the market offers new models and techniques with options that they make it easier or they decrease operative times for the odontologist and including a tendency to recommend less use of alloys which don't have great contents of precious materials titanium or ceramic and suggest machinated techniques instead of the old cast technique. This in vitro study accomplishes an evaluation with the purpose to demonstrate if the dimensional loose changes exist when is used the casting technique with an alloy of Chromo Cobalt and if they exist the realization of compensatory technique or tuning for later comparison with the control that is made of titanium and machinated. We evaluate the samples using microscopy with photo and digital processing to see and evaluate the micro-gap existent to see the similar values in the control sample. The cast structures demonstrated dimensional changes and the setting was not properly adjusted. The rectification of the surfaces of the pillars improved the setting among both structures in a significant manner we also made measurements at the half part zone of the structures these measurements obtained were compared with the control sample 1 most of the values obtained were close to the control values with the exception of one that is away of the tendency lt demonstrates that a rigorous cast technique with rectification l also obtain satisfactory results
dc.identifier.urihttp://repositorio.unab.cl/xmlui/handle/ria/10178
dc.language.isoeses
dc.publisherUniversidad Andrés Belloes
dc.subjectImplantes Dentarioses
dc.subjectRehabilitación Orales
dc.subjectChilees
dc.titleAnálisis digital del ajuste marginal en rehabilitación sobre implanteses
dc.typeTesises
Archivos
Bloque original
Mostrando 1 - 1 de 1
No hay miniatura disponible
Nombre:
a67450_Fukuda_P_Analisis_digital_del_ajuste_marginal_2009.pdf
Tamaño:
24.93 MB
Formato:
Adobe Portable Document Format
Descripción:
TEXTO COMPLETO EN ESPAÑOL
Bloque de licencias
Mostrando 1 - 1 de 1
No hay miniatura disponible
Nombre:
license.txt
Tamaño:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descripción: