Impacto del uso de un protocolo de Weaning en pacientes intubados en la UPC del Hospital Dr. Gustavo Fricke, ViƱa del Ma

dc.contributor.advisorMorales Barrios, Critian AndrƩs
dc.contributor.authorRipetti Fuentes, Arnold Renato
dc.contributor.authorCƔceres Liquitay, Jonathan AndrƩs
dc.contributor.authorGƔlvez Astorga, Miguel Isaac
dc.contributor.editorFacultad de Ciencias de la RehabilitaciĆ³n
dc.date.accessioned2022-06-09T23:29:59Z
dc.date.available2022-06-09T23:29:59Z
dc.date.issued2014
dc.descriptionTesis (KinesiologĆ­a)es
dc.description.abstractSe realizĆ³ una investigaciĆ³n de carĆ”cter descriptivo, transversal, de diseƱo no experimental durante los meses de Septiembre a Noviembre del aƱo 2013, donde se incluyĆ³ a los pacientes en proceso de desconexiĆ³n del Hospital Dr. Gustavo Fricke de ViƱa del Mar, con el objetivo de juzgar el impacto de la aplicaciĆ³n del protocolo de weaning utilizado en dicho centro de salud. Se examinĆ³ el uso de Ć©ste en 17 pacientes, donde se verificĆ³ cada Ć­tem del algoritmo por etapas, su impacto en apoyo ventilatorio no invasivo posterior a extubaciĆ³n, reintubaciones y dĆ­as de estancia en la unidad. Un 64.7% incumpliĆ³ algĆŗn Ć­tem del protocolo contra el 35.7% que lo cumpliĆ³ a cabalidad, lo cual tiende a verse reflejado positivamente en los casos de cumplimiento insatisfactorio del algoritmo en las aspectos examinados. Se logrĆ³ llegar a datos concisos sobre la aplicaciĆ³n del algoritmo en cada etapa, demostrando una importancia decreciente a lo largo de su utilizaciĆ³n asemejĆ”ndolo a un protocolo abreviado de desconexiĆ³n.es
dc.description.abstractResearch descriptive, cross-sectional, non-experimental design was conducted during the months of September to November 2013, the patients of the "Hospital Dr. Gustavo Fricke" of ViƱa del Mar that were in the process of disconnection were included, with the aim ofjudge the impact of the weaning protocol application used in this hospital . Using it in 17 patients, each item of the algorithm was verified in stages, its impact on non-invasive ventilatory support after extubation, reintubation and length of stay in the unit was examined. A 64.7 % breached any protocol item against 35.7 % that it complied fully, which tends to be reflected positively in cases of breach of the algorithm in the aspects examined. It managed to reach concise data on algorithm application in each stage, showing a decreasing importance along its application, assimilating it to an abbreviated weaning protocol.
dc.identifier.urihttps://repositorio.unab.cl/xmlui/handle/ria/22767
dc.language.isoeses
dc.publisherUniversidad AndrƩs Belloes
dc.subjectVentiladores MecƔnicoses
dc.subjectCuidados CrĆ­ticoses
dc.subjectRespiraciĆ³n Artificiales
dc.subjectTĆ©cnicaes
dc.titleImpacto del uso de un protocolo de Weaning en pacientes intubados en la UPC del Hospital Dr. Gustavo Fricke, ViƱa del Maes
dc.typeTesises
Archivos
Bloque original
Mostrando 1 - 1 de 1
Cargando...
Miniatura
Nombre:
a108867_Ripetti_A_Impacto_del_uso_de_un_protocolo_2014.pdf
TamaƱo:
903.52 KB
Formato:
Adobe Portable Document Format
DescripciĆ³n:
TEXTO COMPLETO EN ESPAƑOL
Bloque de licencias
Mostrando 1 - 1 de 1
No hay miniatura disponible
Nombre:
license.txt
TamaƱo:
1.71 KB
Formato:
Item-specific license agreed upon to submission
DescripciĆ³n: